Decorative Graphic
Important Notice
This Inari Medical website and all product offerings listed are tailored for the United States only. Please be aware that product availability and regulatory claims may vary in other regions we serve, including Europe, the Middle East, and Africa (EMEA), Asia-Pacific (APAC), and Latin America/Canada. Inari Medical is currently developing separate websites for our products tailored to these other global and regional markets.
Decorative Graphic
Confidence during complex DVT*
and IVC thrombectomy cases
Protrieve
 Sheath
Compatible with RevCore, ClotTriever®
and FlowTriever® platforms for
simplification of complex thrombectomy
Checkbox
Trap Emboli
33.5mm self-expanding nitinol mesh
funnel allows full wall apposition in
the IVC
Checkbox
Seamless Venous Access
20 Fr sheath designed for right
IJ access and optimal positioning
within the IVC
Triever16®, Triever20®, FlowTriever catheters (S - M - L - XL), and FlowTriever2 catheter
ProTrieve Overview
KEY FEATURES
ProTrieve Device
Aspiration Capable
to clear thrombus
trapped in funnel
Side Actuators
for easy deployment and
recapturing of funnel
ProTrieve Graphic
Self-expanding
nitinol mesh funnel
ProTrieve Device
A BETTER APPROACH
TO THROMBOSED IVC
FILTER RETRIEVALS
  • 20 Fr sheath enables optimal placement in the IVC
    to telescope compatible* filter retrieval sheaths
  • 33.5 mm wall apposing funnel traps emboli from
    thrombosed IVC filters
*The telescoped IVC filter retrieval sheath must be ≥65cm. 45cm sheaths are not compatible with Protrieve sheath.
*Complex DVT defined as bilateral DVT with or without thrombosed IVC

Indications for Use:
The ClotTriever thrombectomy system is indicated for: (1) The non-surgical removal of thrombi and emboli from blood vessels. (2) Injection, infusion, and/or aspiration of contrast media and other fluids into or from a blood vessel. The ClotTriever thrombectomy system is intended for use in the peripheral vasculature including deep vein thrombosis (DVT). The Protrieve Sheath is indicated for use as a conduit for the insertion of endovascular devices into the vasculature while minimizing blood loss associated with such insertions. The FlowTriever retrieval/aspiration system is indicated for (1) the non-surgical removal of emboli and thrombi from blood vessels (2) injection, infusion and/or aspiration of contrast media and other fluids into or from a blood vessel. The FlowTriever retrieval/aspiration system is intended for use in the peripheral vasculature and for the treatment of pulmonary embolism. Triever catheters are intended for use in peripheral vasculature and for the treatment of pulmonary embolism. Triever catheters are also intended for use in treating clot in transit in the right atrium, but not in conjunction with FlowTriever Catheter. The FlowTriever2® catheter is indicated for the non-surgical removal of emboli and thrombi from peripheral blood vessels. Injection, infusion, and/or aspiration of contrast media and other fluids into or from a blood vessel. The FlowTriever2 catheter is intended for use in the peripheral vasculature. The RevCore Thrombectomy Catheter is indicated for: (1)The non-surgical removal of thrombi and emboli from blood vessels. (2) Injection, infusion, and/or aspiration of contrast media and other fluids into or from a blood vessel. The RevCore Thrombectomy Catheter is intended for use in the peripheral vasculature.

Refer to IFU for complete Indications for Use, contraindications, warnings, and precautions.

Caution: Federal (USA) law restricts this device to sale by or on the order of a physician.

All trademarks are property of their respective owners.